• Skip to primary navigation
  • Skip to main content
  • Skip to footer
  • RE-OPEN STRATEGIES
  • Careers
  • ATS Companies
  • (425) 251-9680
  • Facebook
  • LinkedIn
  • Constant Contact
  • Search

ATS Automation

Smart Building Control Systems Serving Western and Central Washington

Building Solutions


  • Controls
  • Energy Optimization
  • Service
  • Home
  • About
    • ATS Companies
    • Vision & Values
    • Team
    • Community
    • Careers
    • Testimonials
  • Solutions
    • Construction
    • Critical Facilities & Data Centers
    • Energy Management
      • Washington Clean Buildings Performance Standard (HB-1257)
    • Smart Building Solutions
      • FacilityAI Autonomous Optimization
    • Consulting Services
  • Support
    • 24/7 Service
    • Service Programs
    • Training
    • Operational Tech
      • FacilityHost
      • FacilityShield
  • Projects
  • Products
  • Contact
  • (425) 251-9680
  • Facebook
  • LinkedIn
  • Constant Contact

Commercial Office Projects

Commercial Office

2U Building Image

2+U Seattle

September 22, 2022

The 2+U office tower located on the corner of Second and Union in downtown Seattle features 686,000 square feet of Class A office space as well as retail and outdoor covered open space. ATS provided control of the DOAS system, central plant chilled beams, heat recovery, condenser water system, AHUs, garage ventilation, lighting control, and more.

The building features a 19-story podium and a 38-story tower with unobstructed views of Elliot Bay. The podium, lifted 85 feet from street level, provides an open-air public gathering area with retail shops. The facility is LEED Platinum Core and Shell certified and Well Health-Safety rated.

Expedia Headquarters

March 2, 2022

Expedia developed 40 acres of Seattle’s Elliot Bay waterfront for their 3-story, one million-plus sqft corporate headquarter to meet their growing business needs. The facility was designed with sustainability in mind and has obtained LEED Gold, Salmon-Safe, and Sites V2 Gold certifications. ATS provided the facility with an integrated Alerton building automation system that gives the facility operators campus-wide control of the CUP, boilers, chillers, electrical metering, and much more.

Alaska Air Hub Image

Alaska Air Hub

March 8, 2021

ATS provided a complete Alerton building management system for Alaska Air Group’s new 128,000 square-foot Hub facility. Located across the street from Alaska Air Group’s corporate headquarters in Seatac, WA, the Hub provides additional office space for employees and a company merchandise store.

ATS partnered with McKinstry as part of the mechanical design-build team, providing preconstruction services such as evaluating mechanical systems and identifying opportunities for value engineering. Evaluating mechanical systems before control design allowed for lower-cost control system installation and provided options to choose the most effective means of delivering value to the development team.

Aside from preconstruction activities, ATS provided control and monitoring of the facility’s DOAS units and other heating and cooling systems. ATS also provides facility analytics, electrical metering, and critical alarm generation.

Seattle Spheres Project Image

The Spheres

December 2, 2019

The Spheres located in downtown Seattle, WA provide a direct link to nature within an office setting. Consisting of three intersecting spherical domes the facility combines working and meeting space with plants from the cloud forest region of over 30 countries.

ATS provided an integrated building automation system featuring Alerton Controls coupled with Aircuity for monitoring of air quality, temperature, humidity, and ventilation control. These integrated systems control the facility’s office and retail spaces and keep more than 40,000 plants from around the world alive and thriving by maintaining an ideal climate. Other system integrations on this project include lighting, plant watering, and electrical meters.

 

 

Sunset Corporate Campus ATS Project

Sunset Corporate Campus

October 19, 2017

VAV Box Controller Retrofit

Diagram of energy savings forSunset Corporate CampusThe building automation system (BAS) at Sunset Corporate Campus (SCC) Building #2 has gone through several modifications since its construction in the 1990s. The BAS was originally installed as a full LON system, but began transitioning to BACnet when the graphical user interface became obsolete in 2011.

In 2013, as part of a tenant improvement project ATS began converting AHUs and VAV terminal units to Alerton’s BACnet line of Visual Logic Controllers. However, after project completion, 126 VAV boxes remained on the LON system.

To retrofit the remaining LON controllers to BACnet devices, the ATS Energy Group took advantage of Puget Sound Energy’s (PSE) Major HVAC Controls Upgrade incentive program. The program offers incentives of up to 50% of total project cost based on post upgrade building energy performance. To maximize incentive dollars, ATS developed and implemented high-performance VAV sequences in addition to retrofitting the controllers. The sequences at SCC now exceed the 2015 Washington State Energy Code for high efficiency VAVs.

High Performance Sequences & Scope Deployed at SCC

  • Dynamic ASHRAE 62.1 AHU Minimum Outdoor Air Resets
  • Trim & Respond AHU Discharge Air Temperature & Duct Static Pressure Resets
  • VAV Discharge Air Temperature Control to Alleviate Stratification Issues Rogue Zone Identification & Automatic Elimination from Reset Sequences
  • Zone Reset Importance Multipliers
  • Detailed Functional Performance Testing
  • Test & Balance for Zone Flow Coefficients, Duct Static Set Points, & Building Static Set Points

Result

There has been an average savings of 28% in total building energy usage (474,246 kWh through 7 months). This is significant savings for what was ostensibly a retrofit of 126 VAV box controllers. The majority of savings came from the added high performance sequences deployed with the new and existing Alerton controllers.

SCC has received $49,000 in utility incentives and is set to receive an additional $61,000 if performance persists for 12 months. After Measurement & Verification, the incentive program will effectively pay for 50% of the total project cost and SCC will benefit from ongoing energy savings from the enhanced sequences.

kWh Usage Comparison to Baseline Data — Average 28% Reduction

Project completed in October 2016. kWh comparison of baseline model and 2016 consumption data.

kWh Usage Comparison Graph for Sunset Corporate Campus

Download Full Case Study

 

Block 44 Advanced Fault Detection & Analytics

Block 44 | Advanced Fault Detection & Analytics

August 16, 2017

Keeping a New Building Like New

Diagram of energy savings for Block 44 | Advanced Fault Detection & AnalyticsIn the first 3 to 4 years of operation, “building performances typically deteriorate as much as 30%.”[1] Block 44, located in Seattle’s South Lake Union technology hub, is managed and operated by CBRE. Completed in 2014, Block 44 is a 395,000 ft² Class A, LEED Platinum certified office building. Even though Block 44 is a new building, setpoint and sequence modifications, manual system overrides, tenant activity, deferred maintenance, and space-use changes can lead to operational drift within the building automation system (BAS) and ultimately inefficient building performance. Wanting to ensure like-new building operation was maintained at the facility, CBRE turned to ATS for solutions.

ATS facilityCARE Informatics

ATS augmented CBRE’s existing controls support agreement by adding their data informatics service, facilityCARE. The ATS facilityCARE service identifies energy and cost saving opportunities through ongoing machine-based commissioning, advanced fault detection, reporting, energy monitoring and analytics.

ATS integrated facilityCARE software into Block 44’s Alerton BAS and began holding monthly system operation and performance reviews with CBRE to discuss operational deficiencies and develop a path for improvement. By combining an extensive library of automated analytics and fault detection with facility operations expertise, ATS proactively identified system inefficiencies and solutions that would not have been detected during normal day-to-day maintenance activities.

Result

The ATS facilityCARE service allowed CBRE to move from a traditional facility operations approach to one of continuous facility improvement, driven by data. Through the data, ATS identified thousands of mechanical and control system operational faults that would typically lead to building performance deterioration. By cataloging and prioritizing system faults for correction, cumulative system runtime was reduced by 35,000 hours in the first year. Even with rising occupancy, and the tendency for building performance to deteriorate as much as 30% in the first few years, the total energy consumption was reduced by 6% year-over-year. In addition, the facilityCARE process identified more than $10,000 in electrical system issues that were resolved through warranty, at no cost to the building ownership

Download Full Case Study

 

 

 

1111 3rd Ave ATS Project

1111 3rd Ave

August 8, 2016

Diagram of energy savings for 1111 3rd AveWith 34 Stories and more than 580,000 square feet, 1111 Third Avenue is an icon of the Seattle Skyline. This high profile building also had a high energy profile. The building owner and property manager partnered with ATS as their energy services professional to increase building efficiency. ATS developed a three-year energy conservation plan inclusive of capital efficiency projects and operational optimization measures.

Seattle City Light Pay for Performance

ATS was one of three companies chosen to be part of Seattle City Light’s (SCL) Pay for Performance (PfP) program. PfP was a three-year pilot program designed to provide energy efficiency incentives while ensuring projects deliver energy savings year over year. PfP required monthly performance verification by comparing the building’s energy consumption on a 15 minute interval basis to a baseline energy model with adjustments for weather and other building variables. To manage the PfP program, 1111 Third Avenue turned to ATS’s Energy Group.

Energy Conservation Measures

Floor Isolation Dampers

Supply air isolation control dampers installed to eliminate conditioned air delivered to unoccupied floors.

High Efficiency Chiller

Aging 550 ton chiller replaced with new high efficiency chiller.  New high efficiency chiller used as first stage of chilled water cooling.

AHU VFDs

Variable frequency drives added to 12 AHU variable-pitch Joy axial fans—1,060 total HP.

Variable Flow Plant Mods

1,100 ton chilled water plant modified from a constant flow to a variable flow system.

Optimized Plant Sequences

Optimized CHW variable flow, CHW reset, CW reset, and cooling tower control sequences implemented.

Garage Lighting Upgrades

Garage lighting replaced with high efficiency lamps and occupancy sensors added to perimeter lights.

 

Savings Details

Since ATS began implementing energy conservation measures at 1111 Third Avenue the energy consumption has dropped considerably, despite a 26% occupancy increase. 1111 Third Avenue now enjoys a smaller ecological impact and greater ongoing financial savings.

Download Full Case Study

 

 

Seattle Philanthropic Foundation Project

Seattle Philanthropic Foundation

June 12, 2014

The headquarters for this Seattle based philanthropic and research center is 875, 000 ft2 and is located on a 12 acre site near the Seattle Center. It includes office space, meeting and convening areas, a visitor learning center, a large atrium, café, data center and two levels of below grade parking. The project received LEED Platinum certification. ATS installed Alerton controls and implemented energy saving sequences for the AHUs, under floor cooling, chilled water plant, water storage, etc.

 

428 Westlake Seattle Project

428 Westlake

June 12, 2014

This 80, 000 sq. ft. building houses corporate offices, retail space, and a three-floor parking garage. ATS designed and provided Alerton controls on all of the HVAC work, including a standard delivery VAV system which serves the retail areas, locker room, and the lobbies. The dual rooftop AC units with interconnecting supply duct allow use of one unit, the other, or both, depending on load conditions. The elevator shaft is pressurized when in fire mode. The plumbing system includes shell and core toilet rooms, locker rooms, retail toilet rooms, waterless urinals, a rainwater leader system, and a garage waste system. Many sustainable and energy efficient practices were implemented in this project. The Alerton DDC control system is accessible via web browser.

 

ATS Projects

5th and Yesler

June 11, 2014

The 5th & Yesler building is a newly constructed 17-floor mixed office and retail building that accommodates 275, 000 sq. ft. of net rentable space and a four-level, 210-stall parking garage.

ATS provided Alerton controls for the AHUs and over 250 VAVs and central plant.

 

Footer

Featured Projects

Providence Regional Medical Center
Central Washington University
Hyatt Hotel and Olive 8 Residences

Seattle Area Office: 450 Shattuck Avenue South, Renton, WA 98057 • (425) 251-9680

Boise Office: 10951 W. Emerald Street, Boise, ID 83713 • (208) 887-9696

Centennial Office: 8200 S Akron Street, Ste. 117, Centennial, CO 80112 • (303) 799-1887

Atlanta Office: 10 Mansell Ct. E, Suite 200, Roswell, GA 30076 •  (770) 649-6100

Spokane Office: 9507 E. Sprague, Spokane Valley, WA 99206 • (509) 892-1000

 

Top
Copyright © 2023 ATS Automation, all rights reserved. Website by Sundog Media, LLC Logo Sundog Media, LLC · Privacy Policy · CCPA Policy · RGA Machine Readable Files